We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.
Categories

300mA Medical X Ray Machine YSX300

Model: YSX300
300mA Medical X Ray Machine YSX300:can cover all body parts, undertake general radiography and obtain clear images.
  • ModelYSX300
  • BrandYSENMED
  • PriceGet Price
  • MOQ1
  • Ship FromFrom Guangzhou,China
  • ShippingAny shipping terms convenient for customers
  • -
    +
    Categories:Floor-mounted Xray Machine
    Share:
    Description Get Price Review

    USE
    General radiography, Filter-ray-filter radiograph
    Unit Configuration
    Control, HT generator unit, Ht cable, X-ray tube unit, Radiographic table-X-ray source column, Collimator
    Function
    The unit can used for general radiography, Bucky radiography of body’s head, chest, foot and hand, bones in lying
    Feature
    1. meter-indicating
    2. single-table single tube
    3. single-phase, full wave rectification
    4. stationary anode x-ray tube assembly
    5. X-ray tube filament s voltage regulator, space charge compensator
    6. Radiograph plain table wimple structure and easy assembling

    MAIN TECHNICAL INDEXES

    ITEM

    CONTENTS

    INDEX

    Demand of power supply

    Capacity

    Two-phase 30KVA

    Voltage Frequency

    380V/220V   ±1050HZ ±0.5Hz

    Intemal resistance

    2Ω(380V)  0.6  Ω(220V)

    power supply

    Adjustable range

    380±10% at220V being adjustable continuously

    Radiograph

    Voltage

    50-90KV

    current

    Small focus: 15mA,Big focus:30mA 60mA 100mA 125mA

    time

    0.04~6.35s 23grades together grading a according to R10 coefficient

    High-voltage generator

    Capacity

    7KVA

    Max DC output voltage

    90KV

    Max DC output current

    125mA

    X-Ray tube

    Model

    XD4-2.9/100

    Focus

    Small focus 1.8×1.8mm  big focus4.3×4.3mm

    Radiographic table

    Length*width*height of bed surface

    2000mm*665mm*700mm

    Moving range of bed surface

    640mm in Length

    Ray-filter of table

    Travel in length ≥50mm

    Grid density N=28

    Convergence distance f.=100cm

    r=8/Grid ratio r=8

    Column of X-ray tube unit

    Moving Longitudinally along Radiographic table

    1000mm or 1800mm

    Distance to friend as moving up and down (along column)

    650~1800mm

    Rotary around the center of cross arm

    ±180°

    Rotary around the shaft line of X-ray annular tubes 

    -10°~60°~  +120°

    Max size of cassette

    356mm×432mm(14×17)

    Note: We will not make another notice if the contour of product and technical parameters will be changed

     

    Net Weight:                 Gross: 695             Packing Size: 230*112*111



    Write down your demand below and we will contact you within 24h!

    1/3
    X